Calibration Services
OVERVIEW
Calibration Services
DC Power
Instruments which measures DC Power can be calibrated under our NABL scope. For eg. DC Power Meter
Micro Pipette & Glassware Calibration
Covering calibration of Micro pipettes (100 ul to 1000 ul), Glass pipettes (Graduated / Non graduated) Glass Burette, Measuring Cylinder, Volumetric Flask, Conical Flask, Beakers (1 ml to 100 ml) etc.
Low Temperature Calibration
Covering calibration of temperature & humidity indicator with sensor, hygrometers, humidity sensors, data loggers, humidity chambers, environmental chambers, climatic chambers etc.
Humidity Calibartion
Covering calibration of temperature & humidity indicator with sensor, hygrometers, humidity sensors, data loggers, humidity chambers, environmental chambers, climatic chambers etc.
Sound Level Meter Calibration
Calibration can be done of Sound Level Meter, dB Meter, Noise Level Meter etc. under NABL.
OVERVIEW
Mass & Balance Calibration
We have got F1 class Stainless Steel weights (1 mg to 200 g) & F2 class Stainless Steel weights (500 g to 10 kg) combined with Mettler Toledo highly precise & high repeatability Weighing Balance that can provide Calibration facility for weights up to 200 g and balance calibration up to 10 kg.
- Temperature Indicator / Controller – Thermocouple type
- Temperature Indicator / Controller – RTD type
- Colorimeter
- Temperature Scanners
- Electronic/Optical Temp. Pyrometer
- Glass Thermometers
- Dial Type Thermometers
- Lab Ovens / Incubators / Furnace
- Autoclaves
- Thermograph – Recorders
- Synchronous Timers / Stop Watches
- Kelvin Bridge
- Analytical Balance (1 miligm to 200 gms.)
- Blood Storage Systems & Walk-in-Cooler
- Centrifuge Machines
OVERVIEW
Infrared Thermometer Calibration
By using Black Body source we do provide calibration services for Infrared Thermometer, Laser Temperature Gun, and Pyrometer etc.
Covers the range from 0° c to 1200°c.
OVERVIEW
Temperature Measuring & Controlling Instruments
Temperature indicators & controllers having thermocouple inputs & RTD inputs, both can be calibrated by simulation method. The input is simulated by using Handy Calibrator ( Yokogawa make).
- Temperature Indicator / Controller – Thermocouple type
- Temperature Indicator / Controller – RTD type
- Temperature Transmitters
- Temperature Recorders
- Temperature Scanner
OVERVIEW
Mechanical Instruments
We shall get mechanical instruments calibrated from our business associate.
- Vernier Calipers
- Micro Meters
- Bore Gauges
- Height Gauges
- Bevel Protractor
- Measuring Scales & Tapes
- Torque Wrench
- Plug & Snap Gauges
- Dial Calipers
OVERVIEW
Liquid Flow Meter & BTU Meter Calibration
Flow Meter Calibration
The flow meter is calibrated by Calibrated Ultrasonic Flow meter. It has got two sensors which is mounted on pipeline at a specific distance and without disturbing the system flow is measured and compared with device under calibration.
BTU Meter Calibration
In this system, Flow & Temperature is measured by Calibrated instruments. These measured values are used to calculate Energy. This calculated value of Energy and reading of device under calibration is compared.
OVERVIEW
Current Transformer Calibration
For calibration of Current Transformer , we have C.T. calibration Test Bridge, along with Burden Boxes, Current Source & Reference Current Transformers.
The Ratio Error and Phase Angle Error is calibrated against the Reference CTs of 0.1 class up to 1200 A.
OVERVIEW
Thermal Mapping, Temperature Uniformity Serve (TUS), System Accuracy Test (SAT)
Temperature Mapping / Validation / Temperature Uniformity Testing of furnace / ovens , cold chambers etc
This is done by locating various temperature sensors inside the equipment. These are connected to data logger. When actual temperature reaches to desired set temperature , it allows to stabilize & after thermal stabilization temperature readings are noted for 30- 40 minutes or as per requirement. These methods are based on various National & International standards.
System Accuracy Testing & Loop Testing
System Accuracy test is basically to verify the total measuring system. In this case dry block calibrator is used to simulate the furnace temperature. The furnace temperature sensor is inserted in the dry block calibrator along with our master sensor & temperature is set to desired temperature. While carrying out the activity temperature of master sensor is noted & output of furnace thermocouple, temperature indicators etc are checked & compared with master sensor.
OVERVIEW
Pressure Measuring Instruments
Pressure Gauge calibration
Pressure Calibration Facility up to 700 Bar. Reference standards for Pressure measurement are Crystal- U.S.A. make Digital Pressure Gauges and Calibrators that have accuracy of 0.05% of reading and 0.1% of reading.
- Pressure Gauges
- Vacuum Gauges
- Pressure Transmitters
- Differential Process Transmitters
- DPT based level Transmitters
- DPT based Flow Transmitters
- Pressure Switch
- Pressure Recorder
- I to P Converters
OVERVIEW
Watt Meters, Energy Meters, Power Factor Meters and Harmonic Testing
Energy Meter Testing
The MTE-Switzerland make Powerful & Portable Power Source, sources out Three phase Voltage & Three phase Current with Phase Shifting of ±180°. The maximum Voltage output is 480 Volts between phase and neutral & Current output is from 100 mA to 120 A. All test values are generated absolutely synthetically with a high degree of accuracy & stability (0.03 %). Frequency can also be changes from 45 Hz to 60 Hz.
The values of Device under calibration is compared with the Reference Standard (make MTE-Switzerland) of accuracy class 0.05. The Scanner Head which comes along with portable reference meter is used to sense & count pulses & shows the Error measurement of under test meter.
The parameters can be calibrated – Three phase & Single phase Power, Energy Measurement, Percent Error Measurement, Power Factor, Harmonics Measurement etc.
- Power Meters (Watt Meters)
- Kilowatt Meters
- Energy Meters
- KWH Meters
- Power Factor Meters
- Load Manager
- Power Analyser
OVERVIEW
Low Temperature Calibration
Covering calibration of temperature & humidity indicator with sensor, hygrometers, humidity sensors, data loggers, humidity chambers, environmental chambers, climatic chambers etc.
OVERVIEW
Sound Level Meter Calibration
Calibration can be done of Sound Level Meter, dB Meter, Noise Level Meter etc. under NABL.
OVERVIEW
Micro Pipette & Glassware Calibration
Covering calibration of Micro pipettes (100 ul to 1000 ul), Glass pipettes (Graduated / Non graduated) Glass Burette, Measuring Cylinder, Volumetric Flask, Conical Flask, Beakers (1 ml to 100 ml) etc.